The automatic fire extinguishing system has three types of activation
DATE:2024-10-10
Read:
SHARE:
Electrical manual activation: This method is realized by means of an emergency activation button. When the button is pressed, the system will likewise have a delay process to ensure that personnel have time to evacuate. Once the set delay time is reached, the system starts to spray the extinguishing agent.
Mechanical emergency start as a back-up option, its operation and precautions need to be widely recognized. Specifically, when manual activation of the extinguishing device is required, the operator removes the safety pin from the solenoid valve and presses the solenoid valve handle. This action will puncture the fire suppression device diaphragm and initiate the fire suppression process. However, this method of activation is not recommended for use in scenarios such as energy storage containers, mainly due to the potential safety hazards it may pose.
In addition to the choice of start-up method, the construction of the energy storage container fire protection system is also a delicate work. Many details need to be paid attention to during construction, such as the sealing measures of the pressure relief port, the sealing treatment of the emergency start/stop button, and the rainproof measures of the acoustic and visual alarms and bleeder lamps, etc., which are all designed to minimize the risk of electrical short-circuiting.
Gas Extinguishing System and Sprinkler System
When the initial fire occurs, the gas fire extinguishing system can respond quickly and effectively control the fire, winning valuable time for subsequent treatment, while in the case of a large fire and sufficient water resources, the sprinkler system can often be activated to completely extinguish the fire. Even under conditions of insufficient water resources, the sprinkler system can extend the treatment time and reduce losses.
For energy storage containers installed in remote areas without water, it is critical to have an emergency plan in place. For example, a program for the rapid removal of batteries on fire, as well as operational procedures for quickly moving batteries away from the source of the fire using equipment such as forklifts, are critical steps to ensure safety. These need to be prepared and trained in advance, just in case.
In the design of fire protection systems for energy storage containers, comprehensive consideration of various factors and the adoption of scientific and reasonable methods are fundamental to ensuring their safe operation. Through a well-designed fire protection system, we can not only respond in time when a fire occurs, but also minimize the damage and protect the safety of people and property.
Energy Storage Container PACK Level Fire Suppression
The PACK level fire suppression technology for energy storage containers realizes precise monitoring of each battery pack and point-to-point spraying of extinguishing agent through advanced composite detectors and pipeline solenoid valve systems, thus effectively suppressing and extinguishing electrical fires in their incipient stages. Although the cost of PACK-level fire suppression program is relatively high, but in high-risk energy storage application scenarios, the use of this targeted fire suppression design is particularly important.
With the rapid development of new electrical energy storage technologies in China, we have transitioned from the R&D demonstration phase to the early stage of commercialization. The “14th Five-Year Plan” period is a critical period for the large-scale development of the electric energy storage industry, and ensuring safety has become a top priority to support the healthy and sustainable development of the industry. Therefore, the construction of energy storage power plant must put safety in the first place, the cost of safety as an integral part. Only by ensuring safety can we promote the prosperous development of the energy storage industry.
The fire safety of energy storage containers does not only rely on a single solution, but requires a complete and systematic fire solution system from the preliminary design and planning, to construction and installation, to the later operation and maintenance management. Aiming at different types and risks of potential energy storage accidents, designing corresponding fire-fighting solutions and emergency plans is the key to ensure the stable operation of energy storage power stations throughout their life cycle.
The above is a detailed explanation of the three solutions of energy storage container fire protection system, I hope this article can add a helping hand to your understanding. If you get new knowledge or insights from this article, you may wish to leave your views and suggestions in the comments section, your every interaction is our greatest support. If there are shortcomings or errors in the article, we also urge you to give us advice, we will continue to improve and provide better quality content. We look forward to communicating with you and jointly promoting the development of science popularization.
Back
Mechanical emergency start as a back-up option, its operation and precautions need to be widely recognized. Specifically, when manual activation of the extinguishing device is required, the operator removes the safety pin from the solenoid valve and presses the solenoid valve handle. This action will puncture the fire suppression device diaphragm and initiate the fire suppression process. However, this method of activation is not recommended for use in scenarios such as energy storage containers, mainly due to the potential safety hazards it may pose.
In addition to the choice of start-up method, the construction of the energy storage container fire protection system is also a delicate work. Many details need to be paid attention to during construction, such as the sealing measures of the pressure relief port, the sealing treatment of the emergency start/stop button, and the rainproof measures of the acoustic and visual alarms and bleeder lamps, etc., which are all designed to minimize the risk of electrical short-circuiting.
Gas Extinguishing System and Sprinkler System
When the initial fire occurs, the gas fire extinguishing system can respond quickly and effectively control the fire, winning valuable time for subsequent treatment, while in the case of a large fire and sufficient water resources, the sprinkler system can often be activated to completely extinguish the fire. Even under conditions of insufficient water resources, the sprinkler system can extend the treatment time and reduce losses.
For energy storage containers installed in remote areas without water, it is critical to have an emergency plan in place. For example, a program for the rapid removal of batteries on fire, as well as operational procedures for quickly moving batteries away from the source of the fire using equipment such as forklifts, are critical steps to ensure safety. These need to be prepared and trained in advance, just in case.
In the design of fire protection systems for energy storage containers, comprehensive consideration of various factors and the adoption of scientific and reasonable methods are fundamental to ensuring their safe operation. Through a well-designed fire protection system, we can not only respond in time when a fire occurs, but also minimize the damage and protect the safety of people and property.
Energy Storage Container PACK Level Fire Suppression
The PACK level fire suppression technology for energy storage containers realizes precise monitoring of each battery pack and point-to-point spraying of extinguishing agent through advanced composite detectors and pipeline solenoid valve systems, thus effectively suppressing and extinguishing electrical fires in their incipient stages. Although the cost of PACK-level fire suppression program is relatively high, but in high-risk energy storage application scenarios, the use of this targeted fire suppression design is particularly important.
With the rapid development of new electrical energy storage technologies in China, we have transitioned from the R&D demonstration phase to the early stage of commercialization. The “14th Five-Year Plan” period is a critical period for the large-scale development of the electric energy storage industry, and ensuring safety has become a top priority to support the healthy and sustainable development of the industry. Therefore, the construction of energy storage power plant must put safety in the first place, the cost of safety as an integral part. Only by ensuring safety can we promote the prosperous development of the energy storage industry.
The fire safety of energy storage containers does not only rely on a single solution, but requires a complete and systematic fire solution system from the preliminary design and planning, to construction and installation, to the later operation and maintenance management. Aiming at different types and risks of potential energy storage accidents, designing corresponding fire-fighting solutions and emergency plans is the key to ensure the stable operation of energy storage power stations throughout their life cycle.
The above is a detailed explanation of the three solutions of energy storage container fire protection system, I hope this article can add a helping hand to your understanding. If you get new knowledge or insights from this article, you may wish to leave your views and suggestions in the comments section, your every interaction is our greatest support. If there are shortcomings or errors in the article, we also urge you to give us advice, we will continue to improve and provide better quality content. We look forward to communicating with you and jointly promoting the development of science popularization.