From 1960 to 1968, research on evaporative cooling technology was forced back into the laboratory.

So far, the self-circulation evaporative cooling technology in hydro generators and turbine generators on the structure of the program have been successfully completed the small industrial unit prototype test, for the development of a larger capacity level of evaporative cooling unit has laid a solid foundation.
READ MORE
2024-11-11

Data center waste heat heating system

If the waste heat of data center is used to supply heat directly, it requires that the heat discharge of data center is always greater than the user heat load, and it is difficult to achieve a complete match in the time domain.
READ MORE
2024-10-23

Practical air conditioning and ventilation system installation knowledge sharing

Practical air conditioning and ventilation system installation knowledge sharing
Duct Sheet Selection:
Basis: GB50243-2016 “Ventilation and Air Conditioning Engineering Construction Quality Acceptance Specification”.
4.1.4 The air duct system shall be divided into four categories of micro-pressure, low-pressure, medium-pressure and high-pressure according to its working pressure, and the air ducts of the corresponding categories shall be used. Duct category should be divided according to the provisions of Table 4.1.4.
READ MORE
2024-10-21

Estimation of HVAC cooling capacity, pump head, ventilation

The cooling capacity of air conditioners for home use is directly related to the room area, sealing conditions, the number of people, the degree of sunlight exposure and other factors.
Before purchasing an air conditioner, it is best to choose a suitable model and power reasonably according to the size of the room area and air circulation.
READ MORE
2024-10-15

Cooling water systems in water-cooled condensers

The cooling water system in water-cooled condensers can be divided into two categories:
I. Wastewater systems In wastewater systems, the cooling water absorbs heat in the condenser and is discharged into the gutter. When a wastewater system is used, the price of water and the source of water supply are important factors to consider because the water is discharged into the gutter. In some places, the use of wastewater systems is strictly limited due to water shortages and expensive water rates, coupled with the limited capacity of wastewater treatment facilities. Even in some large cities where water is plentiful, the use of wastewater systems should be appropriately restricted for the future of the city.

2, the re-circulating water system in the re-circulating water system, the water leaving the condenser through the pipeline into the cooling tower, cooling in the cooling tower and then into the condenser, recycling.
READ MORE